Skip to lesson
Turn a task you repeat into an AI workflow , back to the course page

Module 1 · Pick the task and brief it

Write the brief

Give the assistant the context it doesn't have: reader, purpose, what good looks like, limits, and what to do when something's missing.

Lesson 3 of 4 10 min 6 steps

Key terms: Brief The context your assistant lacks: who the output is for, what it's for, what good looks like, the limits, and what to do when information is missing., Hallucination Content that's false or not supported by what you gave the assistant, often stated with confidence.

Step 1 of 6

Compare the runs

If your usual request is one line, the assistant fills each gap in it with its own idea of who will read the result and what they need. We sent Claude Opus 5.5 the same made-up week of 25 maintenance tickets two ways: the one line a busy facilities coordinator might type, and a Brief The context your assistant lacks: who the output is for, what it's for, what good looks like, the limits, and what to do when information is missing. for the same Monday summary to the office manager.

What to look for

Claude Opus 5.5, three samples of each request, recorded November 10, 2026. Start with the first sample of each. Which tickets does each one treat as urgent, and what does it say about 3139, the ticket with no room?

Each reply is shown whole. Each reply plays at its recorded speed.

One-line request

Recorded Recorded from Claude Opus 5.5 · 10 Nov 2026

You

Summarize these maintenance tickets for the office manager.

Larkfield Partners: facilities requests
Export: reported Oct 19 to Oct 23, 2026

Ticket | Reported | Room | Requester | Priority | Status | Description
3125 | Oct 19 | 2.14 | Maya Fischer | Normal | Closed | desk lamp flickering. swapped bulb
3126 | Oct 19 | Kitchen 1 | Sam Whitlock | Low | Closed | coffee machine descale light on. descaled
3127 | Oct 19 | Server room | Leon Varga | Urgent | In progress | AC unit in server room off, room at 86F. portable fan in, engineer booked Oct 21
3128 | Oct 19 | 3.05 | Grace Lindholm | Normal | Closed | whiteboard stained, won't wipe clean. new cleaner left in room
3129 | Oct 19 | Mailroom | Paul Brandt | Low | Open | need more shelving for parcels
3130 | Oct 19 | 2.03 | Aisha Rahman | Normal | Closed | radiator banging. bled it
3131 | Oct 19 | 1.07 | Omar Haddad | Normal | Open | blinds stuck half down, cord snapped
3132 | Oct 20 | Restroom fl 2 | Nina Petrova | Normal | Closed | soap dispenser empty and cracked. replaced
3133 | Oct 20 | Bike store | Jonah Reyes | Low | Open | 2 bike hooks broken
3134 | Oct 20 | Stairwell B | Ines Calder | Urgent | Closed | emergency exit sign out on landing between fl 1 and 2. replaced same day
3135 | Oct 20 | 3.09 | Kofi Mensah | Normal | In progress | projector won't connect over HDMI. new cable ordered
3136 | Oct 20 | Reception | Femi Adeyemi | Normal | Closed | visitor sofa stained. cleaners done
3137 | Oct 20 | 2.08 | Ruth Okonkwo | Normal | Open | water dripping from ceiling tile over the printer, put a bin under it. printer still plugged in
3138 | Oct 21 | 2.06 | Lucy Barrow | Normal | Closed | radiator cold. valve was off, turned on
3139 | Oct 21 | | Tessa Morgan | Normal | Open | big meeting room by the lifts, 2 chairs' height levers broken
3140 | Oct 21 | Car park | Victor Osei | Normal | Closed | barrier arm slow to lift. reset by building mgmt
3141 | Oct 21 | Reception | Femi Adeyemi | Urgent | Open | front door card reader dead, door left unlocked overnight. security told
3142 | Oct 21 | 1.12 | Hugo Lambert | Low | Closed | sticky drawer on desk 4. fixed
3143 | | 2.11 | Ben Achterberg | Normal | Waiting on vendor | window stuck shut, room stuffy. glazier quote requested
3144 | Oct 22 | Kitchen 3 | Dev Malhotra | Normal | Closed | fridge smells, cleared out old food
3145 | Oct 22 | 3.01 Boardroom | Marta Silva | Normal | In progress | boardroom screen flickers on video calls. AV company coming Oct 27
3146 | Oct 22 | Rm 1.07 | Clara Novak | Low | Open | blind cord broken in 1.07, can't open the blinds
3147 | Oct 22 | Kitchen 1 | Sam Whitlock | Low | Closed | microwave door handle loose. tightened
3148 | Oct 23 | 1.04 | Elif Kaya | Normal | Open | ceiling light out over desks 1 to 3
3149 | Oct 23 | 3.05 | Grace Lindholm | Normal | Closed | door squeaks. oiled the hinges

Facilities Tickets Summary: Oct 19–23, 2026

25 tickets: 13 closed, 8 open, 3 in progress, 1 waiting on vendor

Needs attention now

  • 1.Front door card reader dead (#3141, Urgent, Open). The door was left unlocked overnight. Security has been told, but there's no fix or vendor booked yet. This is a building security risk.
  • 2.Water leak over printer in 2.08 (#3137, Open). This is logged as Normal, but water is dripping from the ceiling onto a printer that is still plugged in. It's an electrical and fire hazard. Recommend unplugging the printer now and raising the priority to Urgent.
  • 3.Server room AC off (#3127, Urgent, In progress). The room was at 86°F with only a portable fan. The engineer was booked for Oct 21, but the ticket is still open as of Oct 23. Confirm whether the visit happened and what the current room temperature is.

In progress / waiting

  • #3135, 3.09: Projector won't connect over HDMI. A new cable has been ordered.
  • #3145, 3.01 Boardroom: Screen flickers on video calls. The AV company is due Oct 27. Worth noting if there are important boardroom calls before then.
  • #3143, 2.11: Window stuck shut and the room is stuffy. Waiting on a glazier quote.

Open, lower priority

  • #3148, 1.04: Ceiling light out over desks 1–3
  • #3131 / #3146, 1.07: Broken blind cord (see data issues)
  • #3139: Two chairs with broken height levers in the large meeting room by the lifts
  • #3129, Mailroom: More parcel shelving needed
  • #3133, Bike store: Two bike hooks broken

Closed (13)

These were mostly quick fixes: bulb swap, radiators bled or turned on, soap dispenser replaced, sofa cleaned, fridge cleared, coffee machine descaled, microwave handle tightened, sticky drawer, door hinges oiled, whiteboard cleaner supplied, and the car park barrier reset. The urgent emergency exit sign in Stairwell B (#3134) was replaced the same day.

Data issues to tidy up

  • Duplicate: #3131 and #3146 are the same broken blind cord in 1.07. Merge them.
  • #3139 has no room number. It's described only as the "big meeting room by the lifts."
  • #3143 has no reported date.
  • #3137 is likely under-prioritised (see above).

Claude Opus 5.5, 10 Nov 2026 · Request to final output: 13.1 seconds · 1,345 output tokens

Full brief

Recorded Recorded from Claude Opus 5.5 · 10 Nov 2026

You

I'm the facilities coordinator at Larkfield Partners. Every Monday I send our office manager, Martin Kell, a summary of the past week's maintenance tickets. This week's tickets are below.

Who it's for: Martin reads it first thing Monday, usually on his phone before the 9:30 stand-up.

What it's for: he uses it to decide what gets fixed first and what he needs to chase with building management or a vendor.

What good looks like:
- Urgent tickets come first, each with its ticket number, room, the date it was reported, who reported it, and its status.
- Every other open ticket is listed, one line each.
- The open and closed counts match the ticket list.
- Every item has its room.

Limits: it has to fit on one phone screen, so keep it short. Plain text, no tables. Don't guess at causes or costs, and don't add anything that isn't in the tickets.

If something is missing: if a ticket has no room or no date, write "not given". Don't guess.

Larkfield Partners: facilities requests
Export: reported Oct 19 to Oct 23, 2026

Ticket | Reported | Room | Requester | Priority | Status | Description
3125 | Oct 19 | 2.14 | Maya Fischer | Normal | Closed | desk lamp flickering. swapped bulb
3126 | Oct 19 | Kitchen 1 | Sam Whitlock | Low | Closed | coffee machine descale light on. descaled
3127 | Oct 19 | Server room | Leon Varga | Urgent | In progress | AC unit in server room off, room at 86F. portable fan in, engineer booked Oct 21
3128 | Oct 19 | 3.05 | Grace Lindholm | Normal | Closed | whiteboard stained, won't wipe clean. new cleaner left in room
3129 | Oct 19 | Mailroom | Paul Brandt | Low | Open | need more shelving for parcels
3130 | Oct 19 | 2.03 | Aisha Rahman | Normal | Closed | radiator banging. bled it
3131 | Oct 19 | 1.07 | Omar Haddad | Normal | Open | blinds stuck half down, cord snapped
3132 | Oct 20 | Restroom fl 2 | Nina Petrova | Normal | Closed | soap dispenser empty and cracked. replaced
3133 | Oct 20 | Bike store | Jonah Reyes | Low | Open | 2 bike hooks broken
3134 | Oct 20 | Stairwell B | Ines Calder | Urgent | Closed | emergency exit sign out on landing between fl 1 and 2. replaced same day
3135 | Oct 20 | 3.09 | Kofi Mensah | Normal | In progress | projector won't connect over HDMI. new cable ordered
3136 | Oct 20 | Reception | Femi Adeyemi | Normal | Closed | visitor sofa stained. cleaners done
3137 | Oct 20 | 2.08 | Ruth Okonkwo | Normal | Open | water dripping from ceiling tile over the printer, put a bin under it. printer still plugged in
3138 | Oct 21 | 2.06 | Lucy Barrow | Normal | Closed | radiator cold. valve was off, turned on
3139 | Oct 21 | | Tessa Morgan | Normal | Open | big meeting room by the lifts, 2 chairs' height levers broken
3140 | Oct 21 | Car park | Victor Osei | Normal | Closed | barrier arm slow to lift. reset by building mgmt
3141 | Oct 21 | Reception | Femi Adeyemi | Urgent | Open | front door card reader dead, door left unlocked overnight. security told
3142 | Oct 21 | 1.12 | Hugo Lambert | Low | Closed | sticky drawer on desk 4. fixed
3143 | | 2.11 | Ben Achterberg | Normal | Waiting on vendor | window stuck shut, room stuffy. glazier quote requested
3144 | Oct 22 | Kitchen 3 | Dev Malhotra | Normal | Closed | fridge smells, cleared out old food
3145 | Oct 22 | 3.01 Boardroom | Marta Silva | Normal | In progress | boardroom screen flickers on video calls. AV company coming Oct 27
3146 | Oct 22 | Rm 1.07 | Clara Novak | Low | Open | blind cord broken in 1.07, can't open the blinds
3147 | Oct 22 | Kitchen 1 | Sam Whitlock | Low | Closed | microwave door handle loose. tightened
3148 | Oct 23 | 1.04 | Elif Kaya | Normal | Open | ceiling light out over desks 1 to 3
3149 | Oct 23 | 3.05 | Grace Lindholm | Normal | Closed | door squeaks. oiled the hinges

Facilities summary, Oct 19–23
25 tickets: 12 open (8 open, 3 in progress, 1 waiting on vendor), 13 closed.

URGENT

  • #3141 Reception, Oct 21, Femi Adeyemi, Open: front door card reader dead, door left unlocked overnight. Security told.
  • #3127 Server room, Oct 19, Leon Varga, In progress: AC off, room at 86F. Portable fan in, engineer booked Oct 21.
  • #3134 Stairwell B, Oct 20, Ines Calder, Closed: emergency exit sign out, replaced same day.

OTHER OPEN

  • #3137 2.08: water dripping from ceiling over printer, printer still plugged in (Open)
  • #3143 2.11: window stuck shut, glazier quote requested (Waiting on vendor, date not given)
  • #3145 3.01 Boardroom: screen flickers on video calls, AV company coming Oct 27 (In progress)
  • #3135 3.09: projector won't connect over HDMI, new cable ordered (In progress)
  • #3148 1.04: ceiling light out over desks 1–3 (Open)
  • #3131 1.07: blinds stuck half down, cord snapped (Open)
  • #3146 1.07: blind cord broken (Open). Same room as #3131.
  • #3139 Room not given ("big meeting room by the lifts"): 2 chair height levers broken (Open)
  • #3129 Mailroom: more parcel shelving needed (Open)
  • #3133 Bike store: 2 bike hooks broken (Open)

CLOSED: 13 tickets, no action needed.


A few things for you to check before sending:

  • #3137 is marked Normal, but it describes water over a plugged-in printer. I listed it first under Other Open and kept its priority as recorded. You may want to re-flag it as Urgent.
  • #3127: the engineer was booked for Oct 21, but the ticket still shows In progress. It may need updating or chasing.
  • #3131 and #3146 both report a broken blind cord in 1.07. They may be duplicates. I listed both so the counts match.
  • #3139 has no room, and #3143 has no date. Both are marked "not given" as you asked.

Claude Opus 5.5, 10 Nov 2026 · Request to final output: 19.2 seconds · 2,152 output tokens

Step 1 of 6 Compare